Maintenance Object Repair Procedures
555-233-123
10-828
Issue 4 May 2002
64-66,
8 or 16
Flash Data Consistency
Test (#421)
MINOR
OFF
test card-mem a/b l
72-74,
80-82,
9-15,
17-86,
160, 192,
288, 320,
416, 448
4-6,
12-14,
20-22,
36-38,
44-46,
52-54,
68-70
8 or 16
Flash Data Consistency
Test (#421)
MAJOR
OFF
upgrade software
76-78,
84-86,
132, 164,
196, 260,
Table 10-302.
Flash Data Consistency Error Log Entries — Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/
Off
Board
Test to Clear Value
Continued on next page