6. The Standby SPE must be in Standby Mode before issuing the test
tape [a|b] long command. If the Standby SPE is not in Standby
Mode, the additional tests needed to clear Error Type #3329 are not
run. These additional tests also cause the test tape [a|b] long
command to take longer to execute.
7. Test the Standby tape by issuing the test tape [a|b] long command.
Issuing this command whenever the SPE contains an active Error
Type #3329 causes the SPE to undergo a COLD 1 restart. This
restart attempts to load translations and, if successful, it clears the
error.
8. If the problem is not resolved, follow normal escalation procedures.
Only one SPE Tape alarmed
A typical scenario that results in a single minor TAPE alarm follows: The
system boots up on an SPE and cannot read in translations. As a result, a
major alarm against TAPE is raised. The system performs a Level 3
SPE-interchange and then reads in translations from the tape on the “new”
Active SPE. At this point, the major TAPE alarm is downgraded to a minor
TAPE alarm.
Error Type #3329 - Repair Procedure #2 (High or Critical Reliability
System):
1. The tape against which Error Type #3329 has been logged should
reside in the Standby SPE. Issue the status system command to
determine which SPE is active.
If Error Type #3329 is logged against the Active SPE, follow Steps 1
through 3 of “Error Type #3329—Repair Procedure #1 (High and
Critical Reliability Systems).”
If Error Type #3329 is logged against the Standby SPE, follow Steps
4 through 7 of “Error Type 3329 - Repair Procedure #1 (High and
Critical Reliability Systems).”
2. Error while saving translations. Resolve other tape errors, and
reissue the save translations command.
j. Error Type #3841 indicates that a save translations operation failed
because the tape was in use. Wait two minutes, then issue the save
translations command. Try this a maximum of 5 times.
k. Error Type #3842 indicates a save translation failure due to a tape-related
problem. The following procedure is recommended to clear this error.
Error Type 3842 - Repair Procedure:
1. Look in the Hardware Error Log for Error Type #1793. If this error
exists, replace the tape cartridge in the tape unit on which the error
occurred with a new cartridge.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...