Maintenance Object Repair Procedures
555-233-123
10-1336
Issue 4 May 2002
Link Retry Test (#215)
This test sends a message to the journal printer management software process to
make a data call to the extension where the printer device connects to. If the
journal printer link is already up, this test passes without making any data call.
Table 10-494.
TEST #215 Link Retry Test
Error
Code
Test
Result
Description/Recommendation
10
ABORT
Internal system error
20
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
30
ABORT
Internal system error
1. Refer to the
‘‘Procedures for Restoring the PMS Printer
section for instructions.
1010
ABORT
The PMS Printer Link has been busied out to out-of-service.
1. Enter release journal wakeup-log|pms-log command to
release the link from busyout state.
2. Retry test journal wakeup-log|pms-log l command to
execute the test.
FAIL
The link CANNOT be established.
1. Refer to the
‘‘Procedures for Restoring the PMS Printer
section for instructions.
PASS
The link is up.
Continued on next page