PR-MAINT (Maintenance Processor)
Issue 4 May 2002
10-1387
555-233-123
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the MTP Reset Test, for example, you may also clear
errors generated from other tests in the testing sequence.
Notes:
a. Refer to PROCR for a description of these tests.
b. Refer to MEMORY [386 systems only] for a description of these tests.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/
ND
1
1
D = Destructive; ND = Nondestructive
Processor Software Initiated Interrupt Test (#77) (a)
X
X
ND
Processor ROM Checksum Test (#80) (a)
X
X
ND
Processor Non-maskable Interrupt Test (#82) (a)
X
X
ND
Processor Sanity Timer Test (#83) (a)
X
D
MTP Reset Test (#101)
X
D
MTP Dual Port Ram Test (#104)
X
D
MTP Sanity Handshake Test (#106)
X
X
ND
MAP Manager I Loop Around Test (#228)
X
X
ND
MTP Analog Loop Around Test (#103)
X
X
ND
MTP Outpulse Relay Test (#102)
X
X
ND
MTP Aux Loop Around Test (#229)
X
X
ND
Read All Memory Test (#85)(b)
X
ND
Memory Error Detection Test (#87)(b)
X
X
ND
Text Checksum Test (#86)(b)
X
ND
Memory Functional Test (#332) (b)
X
D
Memory Board Check Test (#631) (b)
X
X
ND
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...