
HYB-LINE (Hybrid Line)
Issue 4 May 2002
10-895
555-233-123
PASS
EPF test passed. The message to turn on the power to the
station was successfully sent to the port.
1. Although this test never returns a FAIL result, after
running this test, the Error Log should be checked for any
entries with Error Type 257 to examine the real results of
this test.
2. If Error Type 257 does not appear in the Error Log within
10 seconds after completion of this test, it is safe to
assume that the test sensed no problems with the power
to the station. To verify that the station is powered up
correctly, run a self-test on the station, if available, and
check that all the feature buttons are operating.
3. If Error Type 257 appears in the Error Log, this indicates
some problem with the power to the station. The system
technician should check for a short in the wiring, a
damaged jack, a defective voice terminal, or an incorrect
type of terminal.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use list config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue test board long. This should re-establish the
linkage between the internal ID and the port. If this is not
the case, dispatch to check to ensure that there is a valid
board inserted.
Table 10-325.
TEST #56 Hybrid Electronic Power Feed Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...