PKT-CTRL (Packet Control Circuit Pack)
Issue 4 May 2002
10-1275
555-233-123
The status packet-control C command provides useful information about the
Packet Control circuit pack. This command displays the service state of the circuit
pack and various link-related information. The service state “out” indicates that
service is not being provided and users are being disrupted. Maintenance takes
the Packet Control circuit pack out-of-service due to certain faults, or as a result of
the busyout packet-control C command being run. Refer to the “Status
Commands” section in
Chapter 8, ‘‘Maintenance Commands and
for more information on the status packet-control
command.
Error Log Entries and Test to Clear Values
Notes:
a. This error occurs when maintenance software resets the Packet Control
circuit pack due to an in-line error or certain test failures. Once a threshold
number of these errors occur, maintenance places the Packet Control
circuit pack into an out-of-service state, and a major on-board alarm is
raised on the Packet Control circuit pack.
b. This error occurs due to certain in-line errors and test failures. This error is
very serious, and when it occurs maintenance software immediately
escalates testing to the destructive reset test (#586).
Table 10-476.
Packet Control Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
1(a)
Any
None
MAJOR
ON
reset packet-control C (k)
18
0
busyout
packet-control C
WARNING
OFF
release packet-control C
257 (b)
Any
None
MAJOR
ON
reset packet-control C (k)
513 (c)
0
None
769 (d)
Any
Loop Around Test
(#585)
1025 (e)
1
Parity Circuitry Test
(#584)
MINOR
ON
test packet-control C l
1281 (f)
0
None
1537 (g)
0
None
1793 (h)
0
None
2049 (i)
0
None
2305 (j)
Any
Download Test
(#581)
MAJOR
OFF
reset packet-control C
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...