PR-MAINT (Maintenance Processor)
Issue 4 May 2002
10-1391
555-233-123
10204
FAIL
MTP reported test failure. No loop current detected.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to fail, examine the INADS trunk for
connectivity, and manually check for loop current.
3. If there is no INADS trunk, this test should be disabled. To
disable the test, issue the change system-parameters
maintenance command, and change the Test Remote
Access Port field to “n.” If this test is failing on the Standby
SPE, issue the refresh spe-standby command, and rerun
the test.
4. If the INADS trunk checks out okay, but the test still fails,
check the backplane connector wiring.
5. If the backplane wiring checks out okay, replace the
Processor circuit pack at your earliest convenience.
PASS
MTP detected a loop current on the remote access port.
1. If the system cannot call INADS, or INADS cannot contact
the system, check with the local Central Office for
problems with the INADS trunk, and verify that the INADS
number is correct.
10205
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
10206
ABORT
System could not determine if the testing of the INADS port is
administered.
1. Enter the change system-parameters maintenance
command. Verify that the “Test Remote Access Port?” field
is set to “y.”
2. Retry the command at 1-minute intervals a maximum of 5
times.
10208
ABORT
The remote access port is busy. INADS is probably dialed into
the switch.
1. If INADS is dialed in, the INADS trunk is working. There is
no need to run the test.
Table 10-516.
TEST #102 MTP Outpulse Relay Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...