ANN-PT (Announcement Port)
Issue 4 May 2002
10-159
555-233-123
Notes:
a. The Announcement circuit pack can exhibit a condition that does not allow
recording.
Table 10-52. TEST #205 Channel Administration Memory Array (CAMA) Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
The port may be in use on a valid call.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, and the circuit pack is not in
use, escalate the problem.
2000
ABORT
Response to the test request was not received within the
allowable time period. See Note (a) at end of table for more
information.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
Test failed. Announcements played back on this port may
sound corrupted.
1. Reset the circuit pack via the reset board PCSS
command and then run this test again. If the test
continues to fail, replace the circuit pack (see Warning).
2. If there are recurring alarms on this port caused by this
test failing, replace the circuit pack even if Step 1 works
(see Warning).
!
WARNING:
Replacing the circuit pack results in loss of integrated
announcements. Refer to “General Notes” near the
beginning of this Maintenance procedure.
PASS
This test verifies that the Angel processor can properly set up
this port for playbacks. User-reported troubles on this circuit
pack should be investigated using other port and circuit pack
tests. (Refer to “ANN-BD (Announcement Circuit Pack)”
Maintenance documentation for a description of the circuit
pack tests.)
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...