XXX-BD (Common Port Circuit Pack)
Issue 4 May 2002
10-2005
555-233-123
Hardware Error Log Entries and Test to Clear
Values
Common Port Circuit Pack Maintenance Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test board PCSS sh r 1
1(a)
0
Circuit pack removed
or SAKI Sanity Test
(#53)
MINOR
ON
18(b)
0
busyout board PCSS
WARNING
OFF
release board PCSS
23(c)
0
None
WARNING
OFF
36 (d)
4368
none
125 (e)
None
MINOR
ON
217
2
(f)
2
G3iV1-1.286 or G3iV2-386 only
0
None
WARNING
ON
257
65535
Control Channel
Test (#52)
MINOR
ON
test board PCSS sh r
20
257 (g)
Any
None
267 (f)
0
None
WARNING
ON
513 (h)
Any
None
MINOR
ON
test board PCSS sh
769 (i)
4358
None
1025 (j)
4363
NPE Audit Test
(#50)
test board PCSS l r 20
1281 (k)
Ringing Application
Test (#51)
MINOR
ON
test board PCSS r 2
1538 (l)
Any
None
WARNING/
MINOR
ON
1793 (m)
Neon Test (#220)
MINOR
ON
test board PCSS r 2
3840 (n)
Any
None
3999 (o)
Any
None
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...