
MEMORY
Issue 4 May 2002
10-1095
555-233-123
MEMORY
Refer to MEM-BD (Memory Circuit Pack) for circuit pack level errors.
MIS (Management Information
System)
Management Information System (MIS)/Call Management System (CMS) MO is
used for administering MIS translations, such as trunks and stations. There are no
hardware failures associated with this MO.
To diagnose MIS link hardware errors and alarms, see PI-LINK (Processor
Interface Link) and PI-SCI (System Communication Interface) maintenance
information.
MIS/CMS is an adjunct processor that collects ACD data sent from the system. To
change MIS translations, enter busyout mis at the terminal. When the MIS is
busied out, the system stops sending ACD data to the MIS, and a Warning alarm
is raised. When finished, enter release mis. This clears the Warning alarm and
allows the switch to send ACD data to the MIS.
Error Log Entries and Test to Clear Values
Note:
a. When busyout MIS is issued, no data is sent to the MIS/CMS. To allow
data to be sent to MIS/CMS, issue release mis from the terminal.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name of MO
MEMORY
MAJOR
test memory a/b l c
memory
MO Name (in
Alarm Log
Alarm
Level
Initial Command
to Run
Full Name of MO
MIS
WRN
release mis
Management Information System
Management Information System Error Log Entries
Error Type
Aux Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence.
0
Any
Any
Any
release mis
18(a)
0
busyout mis
WARNING
ON
release mis
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...