PR-MEM (TN2404/TN790 RISC Memory)
Issue 4 May 2002
10-1405
555-233-123
Table 10-524.
TEST #86 Text Checksum Test
Error Code
Test
Result
Description/Recommendation
100
ABORT
The test did not complete within the allowable time period.
1. Retry the command.
1029 2014
2015 2016
2017 2018
2020 2022
2024 2025
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a
description of these error codes.
2500
ABORT
Internal system error
1. Retry the command.
1 - 7
FAIL
The system may or may not continue to operate correctly.
The system may fail later when some action requires
access to the corrupted area of the Text.
1. The Flash ROM should be reprogrammed via the
upgrade software command. The memory card
should contain the same vintage software that is
currently in the system. Refer to the “Software
Upgrade” section in this manual.
2. If the test continues to fail, replace the TN2404/TN790
Processor circuit pack and repeat step 1. (Note that if
you replace the Processor circuit pack, you need to
obtain a new license file.)
PASS
The checksum is correct.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...