Maintenance Object Repair Procedures
555-233-123
10-64
Issue 4 May 2002
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This is an in-line error and can only be resolved over time. This indicates
that no terminal equipment was present when ringing was attempted.
Execute the short test port PCSSpp command, and follow the procedure
for the results of Test #48.
■
40960
—
indicates that too many simultaneous incoming ringing
attempts were made on this board. Only four ports on a board may
be ringing simultaneously. A fifth incoming call will cause an inline
error from the board.
■
40977
—
indicates that no terminal equipment was connected when
ringing was attempted. Run the short Test via the test port PCSSpp
command, and follow the procedure for the results of Test #48.
Table 10-24.
16-Port Neon Analog Line Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
40960
40977
none
15 (b)
Any
Audits and Updates
Test (#36)
18
0
busyout station
<extension>
WRN
ON
release station
<extension>
130 (c)
None
WRN
ON
test port PCSSpp sh
257 (d)
40973
none
513 (e)
Station Present Test
(#48)
WRN
OFF
test port PCSSpp sh r 2
769
Battery Feed Test
(#35)
MIN/WRN
2
2
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
ON
test port PCSSpp sh r 2
1025
Loop Around Test
(#161)
MIN/WRN
2
ON
test port PCSSpp l r 2
1281
Conference Test
(#7)
MIN/WRN
2
ON
test port PCSSpp l r 2
1537
NPE Crosstalk Test
(#6)
MIN/WRN
2
ON
test port PCSSpp l r 2
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...