PR-MAINT (Maintenance Processor [TN2404/TN790
RISC Systems])
Issue 4 May 2002
10-1381
555-233-123
MTP External Modem Present Test (#230)
This test is a nondestructive test on the remote access line, and will run only if the
channel is idle. The test validates the presence of an external modem with a
firmware invoked AT command. The test will pass if the modem responds with
“OK” to the AT command.
1048
ABORT
An External Modem is administered to this port.
FAIL
The Auxiliary channel failed the Loop Back Test. The AUX port
may not be sending any auxiliary data to the auxiliary collection
device.
1. Repeat the command at 1-minute intervals a maximum of 5
times.
2. If test continues to fail, replace the Processor circuit pack.
NOTE:
If you replace the Processor circuit pack, you need
to obtain a new license file.
PASS
The Auxiliary channel passed the Loop Back Test. The
auxiliary port is functioning correctly.
1. If no auxiliary data is being recorded, check the auxiliary
collection device, and verify that it has been set up and
connected correctly.
Table 10-512.
TEST #229 MTP Auxiliary Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...