
Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-120
Issue 4 May 2002
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later
test customer-alarm
Help Messages
If the system technician presses
HELP
after entering “test customer-alarm” on a
simplex SPE system, the following message appears:
Enter [cabinet(1-3)],[’long’ or ’short’],
[’repeat’(1-100) or ’clear’], [’schedule’]
If the system technician presses
HELP
after entering “test customer-alarm” on a
duplex SPE system the following message appears:
For cabinet 1 enter [cabinet(1)];
carrier (A-B),[’long’ or ’short’],
[’repeat’(1-100) or ’clear’], [’schedule’]
For cabinet 2-3 enter cabinet(2-3),[’long’ or ’short’],
[’repeat’(1-100) or ’clear’], [’schedule’]
Error Messages
If the location identifier entered is not valid, the following message appears:
Command aborted; please try later
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
test data-module
Help Messages
If the system technician presses
HELP
after entering “test data-module” the
following message appears:
Enter extension, [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the extension format is invalid, the following error message would be displayed:
Extension invalid
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...