Maintenance Object Repair Procedures
555-233-123
10-1028
Issue 4 May 2002
Figure 10-63.
EPN Expansion Links Connections
Table 10-372.
TEST #229 Serial Channel Local Loop Around Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2033
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
2034
ABORT
Background EPN Maintenance circuit pack maintenance is
running the Serial Channel Local Loop Around Test.
1. Wait 30 seconds, and retry the test a maximum of 5 times.
22901
ABORT
Test disabled via software patch.
Continued on next page
ACTIVE LINK
STANDBY LINK
EXPANSION INTERFACE
CIRCUIT PACK
M
G
R
1
EPN MAINTENANCE CIRCUIT PACK
SERIAL INTERFACES
MGR 1 SERIAL
INTERFACE