Maintenance Object Repair Procedures
555-233-123
10-888
Issue 4 May 2002
Hardware Error Log Entries and Test to Clear
Values
Table 10-322.
Hybrid Line Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
Any
None
WARNING
OFF
15 (b)
Any
Hybrid Audits Test
(#61)
18 (c)
0
busyout port
PCSSpp
WARNING
OFF
release port PCSSpp
130 (d)
None
WARNING
ON
test port PCSSpp sh
257 (e)
40988
None
MIN/WRN
2
2
Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used
in the set options command.
OFF
513 (f)
40965
Hybrid Line Audits
Test (#61)
WARNING
OFF
test port PCSSpp sh r 4
769 (g)
Remote Dig Loop
Around Test (#59)
WARNING
OFF
test port PCSSpp sh r 3
1025
Hybrid & Conf.
Circuits Test (#57)
MIN/WRN
2
ON
test port PCSSpp l r 3
1281 (h)
Local Digital Loop
Around Test (#58)
WARNING
ON
test port PCSSpp l r 3
1537 (i)
40968
None
WARNING
OFF
1793
TDMNPE Crosstalk
Test (#6)
MIN/WRN
2
ON
test port PCSSpp l r 3
2049 (j)
32770
None
2049 (k)
40967
None
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...