Maintenance Object Repair Procedures
555-233-123
10-416
Issue 4 May 2002
1-3
FAIL
DTMF digits were not detected correctly. This may or may not
impact reception of R2-MFC calls.
1. Run the short test sequence via the test port PCSSpp sh
r 1 command.
2. If the problem persists, the system is still operating
properly but system capacity will be reduced. In order to
restore system performance to normal, replace the Call
Classifier circuit pack containing the defective CLSFY-PT
(Call Classifier Port).
101-122
FAIL
Forward or Backward MFC signals were not correctly
generated or detected. This impacts reception of incoming
MFC calls.
1. Run the short test sequence via the test port PCSSpp sh
r 1 command.
2. If the problem persists, the system is still operating
properly but system capacity will be reduced. In order to
restore system performance to normal, replace the Call
Classifier circuit pack containing the defective CLSFY-PT
(Call Classifier Port).
PASS
Tone Detection Verification is successful. The Call Classifier
Port (CLSFY-PT) is able to detect/generate all necessary
tones.
Table 10-155.
TEST #42 Tone Detection Verification Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...