Maintenance Object Repair Procedures
555-233-123
10-904
Issue 4 May 2002
1,2,3
FAIL
No response was received within the allowable time period on
one of the transmissions to the terminal. This indicates that
something is wrong with the data link to the voice terminal.
This could be a sleeping set problem or it may be due to wiring
or an unplugged or defective set.
1. Check for errors in the error log, for example, error 1537.
2. Remotely issue busyout and release busy, and run the
short test sequence on the port to check for other errors
associated with the port or terminal.
3. Check the wiring to the set if it appears that the terminal is
not responding to any tests; otherwise, replace the
terminal and rerun the test.
4. If the test still fails, replace the circuit pack and reconnect
the original terminal.
PASS
Hybrid Line Remote Digital Loop Around Test passed. The
hybrid circuit pack is sending and receiving proper messages
to and from the voice terminal.
1. If problems still exist, investigate using other circuit pack
tests and by examining the station, wiring, and
connections.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use list config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and the
port. If this is not the case, dispatch to check to ensure
that there is a valid board inserted.
Table 10-328. TEST #59 Hybrid Line Remote Digital Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...