MODEM-PT (Modem Pool Port)
Issue 4 May 2002
10-1113
555-233-123
Modem Pool Audit Test (#99)
This audit updates the Modem Pool conversion resource status contained in the
TN758 Pooled Modem circuit pack’s microprocessor. It does not actually test the
Pooled Modem circuit pack; therefore, there are no FAIL codes. The audit can
only be performed on idle conversion resources. If the conversion resource is in
use, the audit aborts.
Table 10-418.
TEST #99 Modem Pool Audit Test
Error
Code
Test
Result
Description/Recommendation
NONE
ABORT
The system was not able to allocate all the necessary
resources to execute this test. An ABORT simply indicates that
the conversion resource was in use when the audit was
performed. No repair action is necessary unless it was known
that the conversion resource was actually idle during the test
(yellow in-use LED was off) or was busied out before the test
was run. If this is the case, a TN758 failure condition may exist
and the following procedure should be used:
1. Busyout both of the TN758 Pooled Modem conversion
resources on the circuit pack containing the failing
conversion resource.
2. If the test continues to abort, replace the Pooled Modem
circuit pack and retest.
3. If the circuit pack fails after replacement, escalate the
problem.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...