RANL-STA (Remote Analog Line (Station) Port)
Issue 4 May 2002
10-1433
555-233-123
Error Log Entries and Test to Clear Values
Notes:
a. Error Type: 1 - These are in-line errors and can only be resolved over time.
■
40960 indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may ring
simultaneously. A 5th incoming call will cause an inline error from
the board.
■
40975 indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure
in the terminal equipment or the type of terminal has a low ringer
impedance. Call the terminal equipment and verify that the terminal
rings. If the terminal does not ring, then replace it. Otherwise, issue
the test port UUCSSpp command, and follow the procedure for
Test #48.
Table 10-543.
Analog Line Error Log Entries
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1(a)
40960
40975
40977
none
15(b)
Any
Audits and
Updates Test
(#36)
18
0
busy-out
station
extension
WRN
ON
release station
extension
257(c)
40973
none
513(d)
Station
Present Test
(#48)
WRN
OFF
test port UUCSSpp sh r 2
769
Battery Feed
Test (#35)
MIN/ WRN
2
2
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
ON
test port UUCSSpp sh r 2
2817(e)
Hyperactive
MINOR
OFF
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...