test board
Issue 4 May 2002
8-421
555-233-123
Output
The following example shows the output from the test board 1c07 short
command. The responses display on a test-by-test basis with one line of data for
each test result.
Field descriptions
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance
Name
The name of maintenance object
Alt. Name
Alternate way to identify maintenance objects.
If the Object is The field contains
station
extension
trunk
xxx/yyy (xxx = trunk group, yyy = member)
private CO line P/xxx (xxx = private CO line group number)
Test No
The test being executed
Result
Test result: Pass, Fail, Abort, Disabled, No Board, or Extra Board.
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test board 01C07 short
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C07 ANL-BD 51 PASS
01C07 ANL-BD 52 PASS
01C0703 ANL-LINE 35 PASS
01C0703 ANL-LINE 48 PASS
01C0703 ANL-LINE 36 PASS
01C0701 ANL-LINE 35 PASS
01C0701 ANL-LINE 48 PASS
01C0701 ANL-LINE 36 PASS
01C0702 ANL-LINE 35 PASS
01C0702 ANL-LINE 48 PASS
01C0702 ANL-LINE 36 PASS
Command Successfully Completed
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...