
Maintenance Object Repair Procedures
555-233-123
10-1946
Issue 4 May 2002
1. Busyout (busyout board UUCSS) and release (release board
UUCSS) the circuit pack.
2. Allow 30 minutes for condition to clear itself.
3. To re-establish circuit pack into service manually, busyout (busyout
board UUCSS), reset (reset board UUCSS), and release (release
board UUCSS) the circuit pack.
4. If error recurs within 15 minutes, replace the circuit pack.
5. If the same error occurs on a different circuit pack, follow normal
escalation procedures.
r. Error Type 3840: Circuit pack received bad control channel message from
switch.
Aux Data:
If Error Type 3999:
And traffic
volume is:
Then:
Does not accompany
Error Type 3586,
Heavy
Circuit pack is in service, but sent
at least half hyperactive
threshold. With heavy traffic, this
is normal.
Does not accompany
Error Type 3586,
Light
Circuit pack is in service, but sent
at least half hyperactive
threshold. With light traffic, this
error indicates a problem with the
circuit pack, its links, or the
equipment attached to the links.
Accompanies Error
Type 3586,
Either Light or
Heavy
Switch removed hyperactive
circuit pack.
4096
Bad major heading
4097
Bad port number
4098
Bad data
4099
Bad sub-qualifier
4100
State inconsistency
4101
Bad logical link
4102
Bad application identifier
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...