DIOD-TRK (DIOD Trunk) [G1.2SE]
Issue 4 May 2002
10-607
555-233-123
Port Audit Update Test (#36)
This test sends updates of the CO port translation for all ports on the circuit pack
which have been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No response
message is expected from the circuit pack once it receives translation updates.
The port translation data includes: ground or loop start trunk, tone or rotary dialing
trunk, rotary dialing inter-digit timing, network balance R/RC, and disconnect
timing.
Table 10-227.
TEST #36 Port Audit Update Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate necessary system resources to run the test.
1. Retry at one-minute intervals a maximum of 5 times.
2100
ABORT
Could not allocate the necessary system resources to run the test.
FAIL
Internal System Error.
1. Retry the command at one-minute intervals a maximum of 5
times.
PASS
This test passed. Translation information was successfully updated
on the circuit pack. User-reported troubles on this port should be
investigated by using other port tests and by examining trunk or
external wiring. If the trunk is busied out, the test does not run, but
returns PASS. To verify that the trunk is in-service:
1. Enter status-trunk to verify that the trunk is in-service. If the
trunk is in-service, no further action is necessary. If the trunk is
out-of-service, continue to Step 2.
2. Enter release-trunk to put trunk back into in-service.
3. Retry the test command.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...