test spe-standby
Issue 4 May 2002
8-483
555-233-123
test spe-standby
This command allows the technician to perform hardware diagnostic tests on the
standby Switch Processing Element (SPE) in a duplex SPE system. This
command tests all MOs in the standby MO. The STBY-SPE MO itself does not
have any defined tests. Instead, tests are run on the following MOs when the test
spe-standby command is run.
Refer to these MOs for more details. This command is only for a High or Critical
Reliability systems.
Feature Interactions
Testing the standby SPE maintenance object makes the standby SPE unavailable
to take over for the active SPE.
MEMORY
DUPINT
PROCR
FL-DATA
SHDW-LNK
DATA-BD
PR-MAINT
PI-BD
SHDW-CIR
DATA-CHL
PI-PT
SPE_SELEC
SW-CTL
CARD-MEM
PKT-CTRL
Action/
Object
Qualifiers
Qualifier Description
Logins
Defaults
Feature
Interactions
test
spe-standby
short
long
repeat
number
clear
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to
repeat until the alarm (if any) is
cleared or a single test in the
sequence fails.
1
Examples:
test spe-standby long
test spe-standby l
test spe-standby s r 2
test spe-standby c
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
init
inads
craft
Test
Sequence
= short;
Repeat = 1
See below
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...