FL-DATA (Flash Data Consistency)
Issue 4 May 2002
10-829
555-233-123
a. The Aux Data field records which SPE was active at the time the Flash
Data Consistency Test failed. An “8” in the log refers to carrier A and a “16”
refers to carrier B.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the Memory Card Insertion Test, for example, you
may also clear errors generated from other tests in the testing sequence.
Notes:
a. See “CARD-MEM” for this test description.
b. The Flash Data Consistency Test does not run in a Standard system.
292, 324,
388, 420,
452
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/
ND
1
1
D = Destructive; ND = Nondestructive
Memory Card Insertion Test (#695) (a)
X
X
ND
Memory Card Format and Read Test (#696) (a)
X
X
ND
Memory Card Match Test (#697) (a)
X
X
ND
Memory Card Write-Protected Test (#698) (a)
X
X
ND
Memory Card Directory Recovery Test (#699) (a)
X
X
ND
Memory Card Translation Data Integrity Test
(#694) (a)
X
ND
Memory Card Erase/Write/Read Test (#693) (a)
X
ND
Flash Data Consistency Test (#421) (b)
X
ND
Table 10-302.
Flash Data Consistency Error Log Entries — Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/
Off
Board
Test to Clear Value
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...