IPMEDPRO (IP Media Processor Circuit Pack)
Issue 4 May 2002
10-933
555-233-123
16384
-
16900
FAIL
A SCOTCH device failed:
1. Issue the busyout board UUCSS command.
2. Issue the reset board UUCSS command.
3. Issue the release board UUCSS command.
4. Issue the test board UUCSS long command.
If the board continues to fail replace the board.
24576
-
24580
FAIL
An ETHERNET device failed:
1. Issue the busyout board UUCSS command.
2. Issue the reset board UUCSS command.
3. Issue the release board UUCSS command.
4. Issue the test board UUCSS long command.
If the board continues to fail replace the board.
PASS
The FPGA device on this TN2302 is operating correctly
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct.
Administer the IPMEDPRO interface if it is not already
administered.
2. If the board was already administered correctly, check
the error log to determine whether the board is
hyperactive. If this is the case, the board is shut down.
Reseating the board re-initializes the board.
3. If the board was found to be correctly inserted in step
1, then issue the busyout board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
This should re-establish the linkage between the internal ID and
the port.
Table 10-341.
TEST #1406 MP Diagnostic Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...