Maintenance Object Repair Procedures
555-233-123
10-1102
Issue 4 May 2002
For example, you may also clear errors generated from other tests in the testing
sequence. The tests in this section do not apply to Combined Modem Pool
conversion resources. The standard Digital Line and/or Analog Line port tests are
run on the ports associated with the Combined Modem Pool. The test descriptions
for those maintenance objects (MOs) should be consulted when repairing
Combined Modem Pool arrangements.
Modem Pool NPE Crosstalk Test (#96)
This test is destructive.
This NPE Crosstalk Test verifies that the NPE is connected only to the desired
time slot and is not crosstalking on other time slots. This test operates exactly like
Test #6 for other types of port circuits but is performed twice in order to test both
NPEs in the Modem Pool Port.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/
ND
1
1
D = Destructive; ND = Nondestructive
Modem Pool NPE Crosstalk Test (#96)
X
D
Modem Pool Conference Test (#97)
X
D
Modem Pool Conversion Resource Loop Around
Test (#98)
X
X
ND
Modem Pool Audits Test (#99)
X
X
ND
Table 10-415.
TEST #96 Modem Pool NPE Crosstalk Test
Error
Code
Test
Result
Description/Recommendation
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of
5 times.
1000
ABORT
System resources required to run this test are not available.
The port may be in use on a valid call. Determine whether
the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of
5 times.
1001
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of
5 times.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...