ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 4 May 2002
10-41
555-233-123
Loop Around Test (#161)
This test is designed to check the on-board transmission capabilities of the NPE
on the analog port.
Table 10-16. TEST #161 Loop Around Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources for this test.
Try (a).
1000
ABORT
System resources required to run this test are not available. The
port may be busy with a valid call.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the service
state of the port. If the port is in use, wait until it is idle before
testing.
3. When the port is idle, retry the command at 1-minute
intervals a maximum of 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system
may be under heavy traffic conditions or it may have time slots
out-of-service due to TDM-BUS errors. Refer to “TDM-BUS” to
diagnose TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy
traffic, retry the command at 1-minute intervals a maximum
of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some tone detectors may be out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors.
3. If neither condition exists, retry the command at 1-minute
intervals a maximum of 5 times.
1004
ABORT
The port was seized by a valid call during the test. The test has
been aborted.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the service
state of the port. If the port is in use, wait until the port is idle
before testing.
3. When the port is idle, retry the command at 1-minute
intervals a maximum of 5 times.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...