Maintenance Object Repair Procedures
555-233-123
10-722
Issue 4 May 2002
LED Use
The LED Control message 038x requests the Angel to drive the Red, Yellow, and
Green LEDs on the face plate of typical port board on or off. On the MAPD, only
the Red LED is controlled by this message. Yellow and Green change requests
received from the switch by the MAPD drive LCD behavior rather than LED
behavior. The switch continues to send the same LED control messages to the
MAPD that it currently sends to all other port boards. The MAPD will handle
proper interpretation of these messages. You should note that the PC on the
MAPD, as well as the switch itself, can control the LEDs and the LCD on the
MAPD.
Port Administration
In administration without hardware, the switch allows administration of up to 32
MAPD ports of any port type. If the port type later reported by the board does not
match the existing type, the switch assumes the board is a MAPD board with a
different configuration and rejects the board. MAPD_DCP_STA and MAPD_
ASAI_STA are the only two types of terminals are allowed on a MAPD board.
Therefore, while administering ports on MAPD using add station form, it will
allow only the terminals mentioned above.
NOTE:
Refer to XXX-BD (Common Port Circuit Pack) maintenance documentation
for circuit pack level errors. See also DIG-LINE maintenance documentation
for related line information.
E-DIG-RES (TN800 reserve slot)
See ASAI-RES.
E-DIG-STA (Emulated Digital Line)
There are 4 tests in the Emulated Digital Line station maintenance test sequence
and only one test path in the test sequence. Once the test sequence is started, all
tests in the test sequence are executed.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to
Run
1
1
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, or D); and SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02, ...).
Full Name of MO
E-DIG-STA
MINOR
test port PCSSpp l
Emulated Digital St.
E-DIG-STA
WARNING
test port PCSSpp sh
Emulated Digital St.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...