
Maintenance Object Repair Procedures
555-233-123
10-1328
Issue 4 May 2002
l. Error Type 2817:
Aux values of concern:
m. The link was taken down by the switch because the threshold for
application protocol violations has been exceeded by the PMS. The
protocol never started and messages were received and/or messages
were received in a state in which they were not expected. (Refer to Error
Type 2817 for recommended strategy.)
n. Link was taken down by the switch because the threshold for link protocol
violations has been exceeded by the PMS. PMS is sending “garbage” to
the switch.
10x
The PMS violated the application protocol. The first message after a
request to initiate a database exchange was not the start of a database
exchange. The message is processed. If this error type with this aux
data value recurs frequently (that is, more than once a month), then
advise the customer to call the vendor of the PMS to check out the
PMS device. Once the PMS Link is successfully established, this error
disappears from the Hardware Error Log. See Note.
20x
The PMS violated the application protocol. The start of a database
exchange was received in a state in which it was not expected. The
message is ignored. If this error type with this Aux data value recurs
frequently (that is, more than once a month), then advise the customer
to call the vendor of the PMS to check out the PMS device. Once the
PMS Link is successfully established, this error disappears from the
Hardware Error Log. See the next Note.
30x
The PMS violated the application protocol. The end of a database
exchange was received when no exchange was in progress. The
message is ignored. If this error type with this Aux Data value recurs
frequently (that is, more than once a month), then advise the customer
to call the vendor of the PMS to check out the PMS device. Once the
PMS Link is successfully established, this error disappears from the
Hardware Error Log.
NOTE:
The PMS should be assessed for adherence to the
PMS/PBX protocol specifications. No alarm is raised
against this error.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...