A Packet Bus failure in the Processor Port Network (PPN) causes Packet
traffic (ISDN-BRI, ASAI) in the Expansion Port Networks (EPNs) to fail,
even though there is no Packet Bus failure in the EPN. This is true because
all Packet traffic requires communication with the Packet Interface 1A2 on
the NetPkt circuit pack (R7si and later systems) or the Packet Control
(PKT-CTRL) circuit pack (pre-R7si systems) in the PPN. Due to this
requirement, a PPN Packet Bus failure must be investigated first whenever
Packet Bus failures occur in multiple port networks.
Error Log Entries and Test to Clear Values
NOTE:
For PKT-BUS, an ON-BOARD alarm indicates a problem with the Packet
Bus itself.
Table 10-472.
PKT-BUS Error Log Entries
Error
Type
Aux Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear
Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
**} This error can occur only in pre-R7si systems.
0
Any
Any
Any
test pkt
1 (a)
1-2
Packet Circuit Pack
Audit Test (#570)
MAJOR
ON
test pkt P l r 2
257** (b)
Any
Packet Control Bus
Loop Around Test
(#571)
MAJOR
ON
test pkt P l r 2
513 (c)
1-24
Maintenance/Test
Circuit Pack Query Test
(#572)
MAJOR
ON
test pkt P l r 2
1793 (d)
Any
none
2049 (e)
1-3
Maintenance/Test
Circuit Pack Query Test
(#572)
MINOR
ON
test pkt P l r 2
2305 (f)
1-24
Maintenance/Test
Circuit Pack Query Test
(#572)
test pkt P l
3329 (g)
1-7 or
1000-1007
none
WARNING
ON
test pkt P l
3585 (h)
Any
none
MINOR
ON
test pkt P l
3841 (i)
Any
none
MINOR
OFF
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...