change synchronization
Issue 4 May 2002
A-17
555-233-123
change synchronization
Help Messages
If the user presses
HELP
after entering “change synchronization” the following
message appears:
Entry is not required
Error Messages
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict.
change system-parameters
maintenance
This command specifies and displays scheduled maintenance operations and
maintenance support functions. It also activates and deactivates INADS alarm
origination during repairs. To deactivate alarm origination:
1. Make a note of the current entries in the Alarm Origination and CPE Alarm
fields so you can restore them later.
2. Change the
Alarm Origination to OSS Numbers
field to neither.
3. Change the
CPE Alarm Activation Level
field to none.
4. If daily scheduled maintenance must remain idle during a maintenance
procedure, set the
Start Time
field to a time after the session ends. If
daily Scheduled Maintenance is running and needs to be deactivated, set
the
Stop Time
field to one minute after the current time.
5. Press
Enter
and verify that the screen displays the message:
Command successfully completed
NOTE:
For earlier releases of system software, disable Cleared Alarm
Notification and Restart Notification before submitting the form.
NOTE:
When finished working on the switch be sure to return all fields to
their original settings.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...