Maintenance Object Repair Procedures
555-233-123
10-1178
Issue 4 May 2002
DS1 OPS Switchhook Inquiry Test (#312)
This test initiates the Switchhook Audit Test. The test queries the switchhook state
of the Off-Premises-Station in switch software. If the state in switch software
disagrees with the state on the DS1 Interface circuit pack. The state in the switch
software is updated to match the state on the DS1 Interface circuit pack.
7 or 8
FAIL
Test failed due to internal system error. Do not replace port
board.
■
Error code 7: the failure occurred during station
translation download (to DS1 Interface circuit pack).
■
Error code 8: the failure occurred during station ringer
update.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
PASS
Trunk translation has been updated successfully. The
current trunk states kept in the DS1 Interface circuit pack
and switch software are consistent.
0
NO
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Check to ensure that the board translations are
correct. Use the list config command, and resolve any
problems that are found.
2. If the board was found to be correctly inserted in step
1, issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and
the port. If this is not the case, dispatch to check to
ensure that there is a valid board inserted.
Table 10-443.
TEST #36 Audit and Update Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...