Maintenance Object Repair Procedures
555-233-123
10-1606
Issue 4 May 2002
Notes:
a. System Technician has busied out the System Printer Link.
b. A failure was encountered while attempting to set up the System Printer
Link. This attempt could have been initiated by either the Report Scheduler
software or link maintenance [automatic link retry or the as the result of a
Link Retry Test (#215) request]. The Aux Data field contains the following
diagnostic information to aid in the correction of the failure:
1. unavailability of system resources (too many active logins to the
system).
2. no data channels (DATA-CHLs) available on the Network Control
circuit pack (DATA-BD).
3. 4- time-out during setup attempt. Most likely due to problem with
physical link or printer status.
4. internal system error. Most likely temporary/sporadic failure.
5. the data module the printer is trying to use is busy with another call.
Use the Status data module command to determine when the port
is available for testing.
Refer to the
‘‘Procedures for Restoring the System Printer Link’’
section for
recommended maintenance strategy.
c. The SYS-PRNT was interrupted because of one of the following reasons:
1. the cable to the SYS-PRNT output device is disconnected;
2. the SYS-PRNT output device is powered off;
3. the data extension to which the SYS-PRNT output device connects
has been busied out;
4. internal software error.
Check the connectivity of the wires and cables among the wall jacket, data
module, and SYS-PRNT output device. Follow the instructions provided in
the
‘‘Procedures for Restoring the System Printer Link’’
section.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...