TIE-DS1 (DS1 Tie Trunk)
Issue 4 May 2002
10-1753
555-233-123
1040
ABORT
This test is not performed for trunk ports administered as
access endpoints.
1. Verify this port is an access endpoint by using display
port.
2. If the port has been administered as an access endpoint,
this test should abort.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals for a maximum of
5 times.
2053
ABORT/
FAIL
1
At least one of the following errors is found on the circuit pack:
1281: Loss of Signal, 1793: Blue Alarm, 2049: Red Alarm,
2305: Yellow Alarm, 1537: Hyperactivity.
1. Look for the above error types in the Hardware Error Log
and follow the procedures given in the DS1-BD tests for the
listed error types.
FAIL
The far-end trunk did not respond to the seizure of the near-end
trunk within the allowable time period. This test could have
associated in-line errors in the error log.
1. 1) Enter list configuration board UUCSS . If the circuit
pack is a TN767B vintage 8 or 9, a failure of test 136
causes a subsequent failure of test 7 due to a firmware
bug. Eventually, the board and all of its ports will be taken
out of service and extraneous on-board alarms will be
generated. Replace the circuit pack with a TN767C V3 or
later.
2. Verify that the ’Trunk Type’ field on the ’Trunk
Administration’ screen matches the trunk type administered
on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error
log. If present, refer to the DS1-BD (DS1 trunk circuit pack)
Maintenance documentation or to the UDS1-BD (UDS1
trunk circuit pack) Maintenance documentation.
4. Retry the test at 1-minute intervals for a maximum of 5
times.
Table 10-645.
TEST #136 DS1 Tie Trunk Seizure Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...