Maintenance Object Repair Procedures
555-233-123
10-856
Issue 4 May 2002
NOTE:
The target circuit packs are automatically busied out before the
firmware is downloaded to them and automatically returned to service
after the download is completed. While a DS1 circuit pack is busied
out, any active calls through that circuit pack are dropped.
2. In the
Target Location
field, type the UUCSS address of each
similar-type, programmable circuit pack (up to 50).
NOTE:
You can only download one image file to a similar type circuit pack at
a given time (for example, to all the TN464GP circuit packs). The
download process does not support broadcasting more than one
image file to different-type circuit packs (for example, from TN464GP
to TN2313BP).
If you do not know the target board locations:
a. Type list configuration all and press
Enter
.
The System Configuration screen (
) appears.
Screen 10-10.
System Configuration screen
b. Look for the “P” suffix in the
Code
column and note the circuit pack’s
UUCSS address in the
Board Number
field.
c. Type the UUCSS address of all similar type circuit packs in the
Target Location
field.
list configuration all
SYSTEM CONFIGURATION
Board Assigned Ports
Number Board Type Code Vintage u=unassigned t=tti p=psa
01A13 IP MEDIA PROCESSOR TN2302AP HW03 FW016 01 02 03 04 05 06 07 08
01A14 CONTROL-LAN TN799B 000002 u u u u u u u u
u u u u u u u u 17
01A15 DIGITAL LINE TN754B 000002 01 02 03 04 05 06 07 08
01A16 BRI LINE TN556B 000006 01 01 02 02 t t 04 04
05 05 06 06 07 07 08 08
09 09 10 10 11 11 12 12
01A PROCESSOR TN2404 000003
01A PROCR INTERFACE 1 TN765 000016 u u u u
01A NETCON/PKTINT TN2401 000003 01 02 03 04 05 06 07 08
01A TONE/CLOCK TN2182B 000001 01 02 03 04 05 06 07 08
01D13 DS1 INTERFACE TN2464BP HW00 FW101 01 02 03 04 05 u u u
u u u u u u u u
u u u u u u u u
u u u u u u u u
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...