Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-472
Issue 4 May 2002
Output
The following example is the output for the test port command and assumes that
the port in cabinet 1, carrier c, slot 7, circuit 1 is an analog port. The responses
display on a test-by-test basis with one line of data for each test result.
Field descriptions
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance
Name
The name of maintenance object.
Alt. Name
The alternate means of identifying the maintenance object.
If the Object is aThe field contains
stationextension
trunkxxx/yyy (xxx = trunk group number and yyy =
member number)
private CO lineP/xxx (xxx = private CO line group number)
Test No
Test being executed.
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted.
Refer to the list of codes by test number for each MO.
test port 01c0701 short
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C0701 ANL-LINE 35 PASS
01C0701 ANL-LINE 48 PASS
01C0701 ANL-LINE 36 PASS
Command Successfully Completed
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...