status synchronization
Issue 4 May 2002
8-391
555-233-123
Output
The following example shows the output for the status synchronization
command.
Field descriptions
Stratum Level
Synchronization stratum level (3 or 4)
Maintenance
Name:
Either
TONE-BD
,
DS1-BD
, or
STRAT-3
.
Physical
Location
Board location of the selected DS1 or tone-clock circuit pack
(cabinet-carrier-slot for a DS1; cabinet-carrier for a tone-clock)
Switching
Capability
Whether the on-line reference for synchronization can be
switched (
Enabled
or
Disabled
)
Excessive
Reference
Switching
High-level description of how many times the synchronization
reference has been switched. If excessive reference switching
is taking place (sync error 1793 is at threshold), this field
displays
Yes
; otherwise
No
displays.
status synchronization
SYNCHRONIZATION STATUS
Stratum Level:4
Maintenance Name: TONE-BD Physical Location: 01A
Switching Capability: Enabled
Excessive Reference Switching: No