UDS1-BD (UDS1 Interface Circuit Pack)
Issue 4 May 2002
10-1929
555-233-123
The list measurements ds1 summary command displays the number of bit
errors detected (
Loopback/Span Test Bit-Error Count
field). Injecting this
single bit error should increment the bit error count of the loopback/span test by
one.
Table 10-688.
TEST #1215 Inject Single Bit Error Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the test ds1-loop UUCSS inject-single-bit-error
command at 1-minute intervals a maximum of 5 times.
1015
ABORT
Ports on the UDS1 Interface circuit pack have not been busied
out to out-of-service.
1. Enter the busyout board UUCSS command to put all trunks
or ports of the UDS1 Interface circuit pack into the
out-of-service state.
2. Retry the command.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...