Maintenance Object Repair Procedures
555-233-123
10-1142
Issue 4 May 2002
Table 10-431.
TEST #566 Hook State Inquiry
Error
Code
Test Result
Description/Recommendation
1
ABORT
Switch hook audit timed out. No response was received
from the circuit pack for information about the switch
hook state.
1. Retry the command at 1-minute intervals a
maximum of 3 times.
2. If the test continues to abort, replace the circuit pack
and repeat the test.
2100
ABORT
System resources required to run this test are not
available.
1. Retry the command at 1-minute intervals a
maximum of 3 times.
Any
FAIL
Internal System Error
1. Retry the command at 1-minute intervals a
maximum of 3 times.
2. If the test continues to fail reset the circuit pack via
the busyout board PCSS, reset board PCSS,
release board PCSS command sequence.
3. Retry the command at 1-minute intervals a
maximum of 3 times.
PASS
Call processing and Maintenance/Test Analog Port
maintenance software agree on the Maintenance/Test
Analog Port hook state.