Maintenance Object Repair Procedures
555-233-123
10-164
Issue 4 May 2002
2. Performing a test board long when the circuit pack is in this state
yields the following abort codes:
■
Ports 1 and 9 abort Test #206 with code 1024
■
Ports 1 and 9 abort Test #205 with code 2000
■
Board level Tests #209 and #210 abort with code 1024
3. The save/restore announcements command times out with:
Error encountered, can’t complete request
The Announcement circuit pack lock-up can be cleared remotely by
performing a soft reset to the circuit pack:
■
busyout board PCSS (this command drops all calls in progress on
the Announcement circuit pack)
■
reset circuit pack using the reset board PCSS command
■
release circuit pack using the release board PCSS command
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...