TAPE-DAT (Tape Consistency)
Issue 4 May 2002
10-1643
555-233-123
Table 10-607.
TEST #421 Tape Data Consistency Check Test
Error
Code
Test
Result
Description/Recommendation
0
ABORT
The test timed out without completing. This error can occur
when the system is heavily loaded and the test is not allocated
sufficient time to run.
1. Rerun the test when the system is less busy and is not
running standby maintenance.
1029
1030
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2051
ABORT
Refer to the STBY-SPE (Standby SPE) Maintenance
documentation for a description of these error codes.
9005
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
35498
ABORT
Difficulty was encountered trying to send information between
the SPEs.
35512
ABORT
The Standby SPE cannot be put into maintenance mode.
1. Resolve all DUPINT (Duplication Interface Circuit Pack),
SHDW-LNK (Memory Shadowing Link), SHDW-CIR
(Common Shadow Circuit), and STBY-SPE (Standby
SPE) alarms.
2. Retry the command.
35514
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...