Maintenance Object Repair Procedures
555-233-123
10-1308
Issue 4 May 2002
1338
ABORT
The test is not allowed to run since a planned SPE interchange
is in progress. A planned interchange may be caused by 24 hour
scheduled testing. During this time the terminal will be held out
of service but it should recover automatically after 3 minutes.
1. Wait 3 minutes and retry the command.
1339
ABORT
The test could not run on a standby Packet Interface because
the standby SPE is unavailable.
1. Refer to the STBY-SPE maintenance documentation for
information on why a standby SPE may be unavailable and
what repair actions should be taken. The status syst
1screen indicates the state of the standby SPE.
Unavailability may be caused by a variety of reasons, such
as the setting the SPE-SELECT switches on the DUPINT
circuit packs to the position of the active SPE, a failure of
the DUPINT circuit pack, or loss of power on the standby
SPE. The
SPE SELECT SWITCH field
on the status syst
1 screen displays
spe a
or
spe b
if the SPE-SELECT
switches are in the a or b position, respectively.
2000
ABORT
Response to the test request was not received within the
allowable time period. Retry the command at 1-minute intervals,
a maximum of 3 times.
2500
ABORT
Internal system error
1. Retry the command.
NO
BOARD
The Packet Interface is not detected as being physically present.
1. Reboot the system, then retry the command. If the NO
BOARD indication persists, replace the TN2401/TN794
NetPkt circuit pack.
1
FAIL
The Private Link Broadcast looparound test failed. The Packet
Interface will enter a fatal fault state when this occurs and the
Packet Interface Maintenance software should put the Packet
Interface in a out-of-service state. Therefore by the time further
action is taken, it is expected that the test will abort with ABORT
code 1137 and a demand reset should be used to test the
Packet Interface.
1. Reset the Packet Interface using the reset
packet-interface CS command. Refer to the repair
procedures for the Packet Interface Reset Test (#889) for
further action.
2. If the test continues to fail, replace the TN2401/TN794
NetPkt circuit pack.
Table 10-485.
TEST #885 Private Looparound Tests — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...