VAL-PT (Voice Announcements over LAN Packet/Port)
Issue 4 May 2002
10-1967
555-233-123
Table 10-705.
TEST #1285 TDM Looparound Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
The port is in use.
Retry the command when the port is idle. You can force the
port to the idle state with the busyout port UUCSS command.
Escalate if the problem persists.
This command is destructive, tearing down all calls and links
using the port.
1002
ABORT
No TDM bus timeslots available for the test.
Retry the command at 1-minute intervals, up to 5 times.
Escalate if the problem persists.
1003
ABORT
No more tone receivers idle for use in this test.
Retry the command at 1-minute intervals, up to 5 times.
Escalate if the problem persists.
2000
ABORT
Did not receive circuit pack test response within the allowable
time period.
If this problem persists, reset the circuit pack (busyout board
UUCSS, reset board UUCSS, and release board UUCSS).
Repeat the test.
If the problem persists, replace the circuit pack.
2012
ABORT
Internal system error.
Retry the command at 1-minute intervals, up to 3 times.
Escalate if the problem persists.
2100
ABORT
Could not allocate the necessary system resources to run test.
Retry the command at 1-minute intervals, up to 5 times.
Escalate if the problem persists.
FAIL
Received tones do not match transmitted tones.
Retry command at 1-minute intervals, up to 3 times.
If the problem persists, refer to TDM-BUS, Tone Generator,
and Tone Receiver repair procedures.
If the problem persists, reset the board (busyout board
UUCSS, reset board UUCSS, and release board UUCSS).
Repeat the test.
If the problem persists, replace the circuit pack.
PASS
Port connections across the TDM bus function properly.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...