
CO-DS1 (DS1 CO Trunk)
Issue 4 May 2002
10-421
555-233-123
Notes:
a. Error Type 1—Aux Data 57408—No tip ground is detected on an outgoing
call.
Aux Data 57487—PBX could not get “loop close” signal (TN767).
The DS1 Interface circuit pack detected a hardware fault. These errors
cause the Dial Tone Test (#314) to run and are only considered a problem if
the Dial Tone Test fails (in which case Error Type 1025 also shows up). In
this case, the trunk may be put in ready-for-service state (shown as
“disconnected” by status command), which allows only incoming calls. Run
the Dial Tone Test (#314) and follow its outlined procedures.
b. Error Type 15—This is a software audit error that does not indicate any
hardware malfunction. Run Short Test Sequence and investigate
associated errors (if any).
c. Error Type 18—System Technician has busied-out the trunk to the
out-of-service state. No calls can be made on this trunk except the Facility
Access Test Call. For details on this feature, refer to “Facility Test Calls”
section in Chapter 5, “Routine Maintenance Procedures”.
d. Error Type 130—This error type indicates that the circuit pack has been
removed or has been insane for more than 11 minutes. To clear the error,
reinsert or replace the circuit pack.
e. Error Type 257—The DS1 Interface circuit pack detects a hardware fault.
The Aux Data field contains the following error type: 57392—no external
release on PBX disconnect [E030]. Escalate the problem.
f. Error Type 513—The DS1 Interface circuit pack detects a hardware fault.
The Aux Data field contains the following error type: 57393—belated
external release on PBX disconnect [E031]. Escalate the problem.
g. Error Type 769—The DS1 Interface circuit pack detects a hardware fault.
The Aux Data field contains the following error type:—57484, fault is
detected on tip/ring [E08C]. Escalate the error.
h. Error Type 1793—DS1 Interface circuit pack is out-of-service. Look for
DS1-BD errors in the Hardware Error Log. Refer to the DS1-BD (DS1
Trunk Circuit Pack) Maintenance documentation for details.
i. Error Type 2562—Retry Failure error. This error is logged only. It is not a
hardware failure and hence does not start any testing or generate any
alarms. This error comes from call processing and is generated when a
second attempt (retry) to seize an outgoing trunk fails.
j. Error Type 2817—Glare error. This error is logged only. It is not a hardware
failure and hence does not start any testing or generate any alarms. This
error is the result of a simultaneous seizure of a two-way trunk from both
the near-end and the far-end. Attempt to place the call again. If the error
persists, execute the Dial Tone Seizure Test (#314) and follow those
procedures.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...