Maintenance Object Repair Procedures
555-233-123
10-108
Issue 4 May 2002
1008
ABORT
Could not allocate a ringing circuit for one of the following
reasons:
■
All the ringing circuits are in use, or
■
The ringing generator is defective, or
■
It is not wired correctly.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, look for RING-GEN errors in
the Error Log. If an ABORT 1008 occurs for Test #48 on
other circuit packs as well, then the ringing generator may
be defective or not wired correctly. If it does not occur on
other ports, then that circuit pack is currently using all four
ringing phases.
1018
ABORT
The test was disabled via administration. The default for the
’Test’ field on the ’Station’ form is ’y’; thus, you may want to
determine why this field has been set to ’n’ on this station (this
may be due to the ringing application test 48, which can be
customer or terminal disturbing).
1. To enable the test for a particular station, enter change
station extension and set the ‘Test?’ field on the ‘Station
Form’ to ‘y.’
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
System resources required to run this test are not available.
Either a system allocation to get information about the port or
to put the port into a service state failed or the attempt to put
the port in connection with a tone source failed (this could be
a tone-clock problem). The tone-clock and tone detectors
could be having a communication problem, for example, the
companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-36.
TEST #48 Station Present Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...