Maintenance Object Repair Procedures
555-233-123
10-706
Issue 4 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. This error indicates that an unexpected hardware reset has occurred on
the Duplication Interface circuit pack. Appropriate action has been taken by
the software to prevent malfunction. However, if this type error occurs with
regular frequency, the DUPINT circuit pack may need to be replaced.
b. There are several possible Aux Data fields for this error, including blank. All
indicate loss of contact with the indicated Duplication Interface circuit
packs.
Table 10-259.
Duplication Interface Circuit Pack Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test dup 1C sh r 1
1
Sanity Circuit Test (#273)
MAJOR/
WRN
ON
test dup 1C l r 1
108 (a)
Any
None
109 (a)
Any
None
257
SAT Loop Back Test (#274)
MAJOR/
WRN
ON
test dup 1C sh r 3
513
SPE A Loop Back Test (#275)
MAJOR/
WRN
ON
test dup 1C sh r 3
769
SPE B Loop Back Test (#276)
MAJOR/
WRN
ON
test dup 1C sh r 3
1025
Sanity Maze Test (#277)
MAJOR
/WRN
ON
test dup 1C sh r 3
1281 (b)
Any
DUPINT Status Query Test
(#315)
MAJOR/
WRN
ON
test dup 1C sh r 6
1537 (c)
Any
Background Test Query Test
(#271)
MAJOR/
WRN
ON
test dup 1C sh r 3
1793 (d)
Any
MBUS Time-Out Query Test
(#285)
MAJOR/
WRN
ON
test dup 1C l r 3
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...