MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 4 May 2002
10-1047
555-233-123
4. At the command prompt, type ping 10.32.64.96 (the IP address of the
internal Motorola MPC860 processor) and press
Enter
.
■
If configured correctly, the system displays:
Reply from nnn.nn.nn.nn: bytes=32 time <##ms
TTL=###
■
If there is no reply:
— Check that the internal cables on the TN802 circuit pack
(Notes 4 and 6 in
) are not
loose.
— Replace the circuit pack.
5. Ping the gateway: at the command prompt, type ping XX.XXX.XXX.XXX
(the IP address of the gateway) and press
Enter
.
6. When finished, at the command prompt type exit and press
Enter
.