WAE-PORT (Wideband Access Endpoint Port)
Issue 4 May 2002
10-1995
555-233-123
Notes:
a. The wideband access endpoint has been busied out by a busyout
access-endpoint <extension> command. No calls can be made to this
extension.
b. The circuit pack has been removed, or it has been insane for more than 11
minutes. To clear the error, reinsert or replace the circuit pack.
c. The Conference Circuit Test (#7) failed on this port. See Test #7 for repair
procedures.
d. The NPE Crosstalk Test (#6) failed on this port. See Test #6 for repair
procedures.
e. There was a failure of the TN464C UDS1 Interface circuit pack. See
UDS1-BD Maintenance documentation for details.
f. The Port Audit and Update Test (#36) failed due to an internal system error.
Enter the status access-endpoint <extension> command and verify the
status of the port. If the wideband access endpoint is out-of-service, enter
the release access-endpoint <extension> command to put it back to
in-service. Retry the test command. If the test continues to fail, escalate the
problem.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the NPE Crosstalk
Test, for example, you may also clear errors generated from other tests in the
testing sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
D = Destructive; ND = Nondestructive
NPE Crosstalk Test (#6)
X
ND
Conference Circuit Test (#7)
X
ND
Port Audit and Update Test (#36)
X
X
ND
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...