MODEM-PT (Modem Pool Port)
Issue 4 May 2002
10-1097
555-233-123
Refer to
while reading the following
paragraph.
Each Modem Pool conversion resource contains two ports. One of these, an
Analog Line Port, is connected (via the PBX network) to the Analog Line or
Central Office Trunk Port that is the source of the modem signal. The second port
is referred to as the digital port and is connected (again through the PBX network)
to the Digital Line or Trunk port associated with the Data Module in the
connection. The analog modem signals enter the analog port of the conversion
resource in standard Pulse Code Modulation (PCM) format but are converted into
Data Communications Protocol (DCP) format before going to the Digital Line or
trunk in the connection.
There are two primary types of Modem Pool conversion resources available: an
Integrated Pooled Modem and a Combined Modem Pool. The integrated TN758
Pooled Modem circuit pack contains two independent 300 or 1200 baud
conversion resources. Each conversion resource contains two interfaces to the
PBX digital network: an analog port and a digital port. The analog port is
connected through the PBX network to the analog line or trunk port containing the
analog modem signals. The digital port connects through the PBX network to the
digital line or trunk port in the call.
shows a typical end-to-end
connection using a conversion resource on the integrated Pooled Modem circuit
pack.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...